  1. G

    Riello rdb won't fire up

    I have done this already I removed 4 bolts on the first plate, the filter was clean, I then removed another 3 bolts and then there was nothing there, there was a few steel cogs and a half moon in the centre that seemed to spin simultaneously, everything looked fine plenty of oil and I definitely...
  2. G

    Riello rdb won't fire up

    Cheers I had a look and it seems to be pointing toward the fuel pump, but would there still be oil coming from the nozzle if this was the problem, how often would a phooresistance go faulty, looks fairly new and is clean so do you reckon it's the fuel pump, cheers
  3. G

    Riello rdb won't fire up

    Well this would probably have happened already from trying to turn it on so many times, leaving it on constant hoping that it would fire up because to honest I think they have a mind of there own sometimes and one thing can lead to another, my friend is a sparks and he should have a multimeter...
  4. G

    Riello rdb won't fire up

    Yeah your right, I only got a service a few months ago through a friend of mine that said he was experienced but he didn't do much, he was only there a half an hour, which i know couldnt have been a proper service, when I cleaned the burner i turned off all power to the house and there wasn't a...
  5. G

    Riello rdb won't fire up

    Yes I have read that, someone used a friends control box to test if it was faulty, do I need the coil lead and wire into the box or do I just change the coil, cheers
  6. G

    Riello rdb won't fire up

    No the blast tube is dry Shane, could it be the solenoid coil, cheers . .
  7. G

    Riello rdb won't fire up

    It's a riello rdb2.2 heatpac s 90/120, also there was oil on the tip of the nozzle cap( when closed ) so there is definitely oil being pumped through the nozzle, I have the electrode assembly 3mm from the tip as per manual instruction but I was wondering if it's anything got to do with that,cheers
  8. G

    Riello rdb won't fire up

    So do you reckon it's just the nozzle, I could blow through the nozzle so could there still be dirt in it, if so do you know where I can purchase one of these, smallmans, ranelagh maybe
  9. G

    Riello rdb won't fire up

    The level is about half a tank and it's kerosene, when I checked the nozzle after I cleaned everything the first time there was oil on the nozzle again, I washed it with petrol and blew the nozzle before putting it back on, didn't seem to be blocked looks fairly new like every other part I...
  10. G

    airlock in oil boiler

    Not too sure, take off the casing on the burner with a screwdriver and there should be a pressure gauge on the bottom left hand side of the burner, grab a 4mm Allen key and loosen the screw slowly, air should come out until the oil runs freely then tighten the screw and hit the reset button...
  11. G

    Riello rdb won't fire up

    Hi, I am new to posting but was just wondering if anybody could help me. My burner comes on like runs till its about to fire up then it makes a one click sound followed by a 3 sec buzzing sound and then goes to lock out and it keeps repeating this all day while pressing the small reset button...